Head on this page. It moves to the text on this page. It moves to the submenu on this page. It moves to the main menu on this page. It moves to the footer on this page.
It is a top of the text.

Line Up

LM2500 Series

LM2500 is an open cycle/2 shaft type gas turbine derived from TF39/CF6-50 engine manufactured by General Electric.
This gas turbine has been popular for the use of electric generator or mechanical driver.

Features of LM2500

  • 1.High thermal efficiency
  • 2.Proven durability through engineered simplicity
  • 3.Light weight and compact design
  • 4.Easy operation and maintenance
  • 5.Multi fuel capability
  • 6.Original control system
  • 7.Steam injected gas turbines (STIG)
  • 8.Single source responsibility
  • 9.Unique skid factory packaging

Performance Data

Fuel Type:Natural Gas

Fuel Type Natural Gas
System Simple Cycle
Power Enhancement at High Ambient Temp. N/A
Model LM2500PJ LM2500RB
Frequency 50Hz 60Hz 50Hz/60Hz
Power Output 20,530kW 21,460kW 31,120kW
Heat Rate 10.59MJ/kWh 10.2MJ/kWh 9.33MJ/kWh
Efficiency at generator terminal 34.0% 35.3% 38.6%
Efficiency for heat recovery - - -
Total thermal efficiency - - -
NOx(O2=16%) 21ppm 21ppm 21ppm

*Condition/Ambient Temp:15℃ Atmospheric Pressure:1013hPa Relative Humidity:60%
*The above performance data is based on the New&Clean condition.

Fuel Type Natural Gas
System Simple Cycle
Power Enhancement at High Ambient Temp. Inlet Air Cooling(Evaporative Type / Chiller Type / Absorbtion Chiller Type)
Model LM2500PJ LM2500RB
Frequency 50Hz 60Hz 50Hz/60Hz
Power Output 20,530kW 21,460kW 31,120kW
Heat Rate 10.59MJ/kWh 10.2MJ/kWh 9.33MJ/kWh
Efficiency at generator terminal 34.0% 35.3% 38.6%
Efficiency for heat recovery - - -
Total thermal efficiency - - -
NOx(O2=16%) 21ppm 21ppm 21ppm

*Condition/Ambient Temp:15℃ Atmospheric Pressure:1013hPa Relative Humidity:60%
*The above performance data is based on the New&Clean condition.

Fuel Type Natural Gas
System Cogeneration
Power Enhancement at High Ambient Temp. N/A
Model LM2500PJ LM2500RB
Frequency 50Hz 60Hz 50Hz/60Hz
Power Output 20,530kW 21,460kW 31,120kW
Heat Rate 10.59MJ/kWh 10.2MJ/kWh 9.33MJ/kWh
Efficiency at generator terminal 34.0% 35.3% 38.6%
Efficiency for heat recovery 51.9% 51.5% 47.7%
Total thermal efficiency 85.9% 86.8% 86.3%
NOx(O2=16%) 21ppm 21ppm 21ppm

*Condition/Ambient Temp:15℃ Atmospheric Pressure:1013hPa Relative Humidity:60% Steam Pressure:0.8MPaG (Saturated) Feed Water Temp:20℃
*The above performance data is based on the New&Clean condition.

Fuel Type Natural Gas
System Cogeneration
Power Enhancement at High Ambient Temp. Inlet Air Cooling(Evaporative Type / Chiller Type / Absorbtion Chiller Type)
Model LM2500PJ LM2500RB
Frequency 50Hz 60Hz 50Hz/60Hz
Power Output 20,530kW 21,460kW 31,120kW
Heat Rate 10.59MJ/kWh 10.2MJ/kWh 9.33MJ/kWh
Efficiency at generator terminal 34.0% 35.3% 38.6%
Efficiency for heat recovery 51.9% 51.5% 47.7%
Total thermal efficiency 85.9% 86.8% 86.3%
NOx(O2=16%) 21ppm 21ppm 21ppm

*Condition/Ambient Temp:15℃ Atmospheric Pressure:1013hPa Relative Humidity:60% Steam Pressure:0.8MPaG (Saturated) Feed Water Temp:20℃
*The above performance data is based on the New&Clean condition.

Fuel Type:Kerosene

Fuel Type Kerosene
System Simple Cycle
Power Enhancement at High Ambient Temp. N/A
Model LM2500PJ LM2500RB
Frequency 50Hz 60Hz 50Hz/60Hz
Power Output 20,530kW 21,460kW 31,120kW
Heat Rate 10.59MJ/kWh 10.2MJ/kWh 9.33MJ/kWh
Efficiency at generator terminal 34.0% 35.3% 38.6%
Efficiency for heat recovery - - -
Total thermal efficiency - - -
NOx(O2=16%) 35ppm 35ppm 35ppm

*Condition/Ambient Temp:15℃ Atmospheric Pressure:1013hPa Relative Humidity:60%
*The above performance data is based on the New&Clean condition.

Fuel Type Kerosene
System Simple Cycle
Power Enhancement at High Ambient Temp. Inlet Air Cooling(Evaporative Type / Chiller Type / Absorbtion Chiller Type)
Model LM2500PJ LM2500RB
Frequency 50Hz 60Hz 50Hz/60Hz
Power Output 20,530kW 21,460kW 31,120kW
Heat Rate 10.59MJ/kWh 10.2MJ/kWh 9.33MJ/kWh
Efficiency at generator terminal 34.0% 35.3% 38.6%
Efficiency for heat recovery - - -
Total thermal efficiency - - -
NOx(O2=16%) 35ppm 35ppm 35ppm

*Condition/Ambient Temp:15℃ Atmospheric Pressure:1013hPa Relative Humidity:60%
*The above performance data is based on the New&Clean condition.

Fuel Type Kerosene
System Cogeneration
Power Enhancement at High Ambient Temp. N/A
Model LM2500PJ LM2500RB
Frequency 50Hz 60Hz 50Hz/60Hz
Power Output 20,530kW 21,460kW 31,120kW
Heat Rate 10.59MJ/kWh 10.2MJ/kWh 9.33MJ/kWh
Efficiency at generator terminal 34.0% 35.3% 38.6%
Efficiency for heat recovery 51.9% 51.5% 47.7%
Total thermal efficiency 85.9% 86.8% 86.3%
NOx(O2=16%) 35ppm 35ppm 35ppm

*Condition/Ambient Temp:15℃ Atmospheric Pressure:1013hPa Relative Humidity:60% Steam Pressure:0.8MPaG (Saturated) Feed Water Temp:20℃
*The above performance data is based on the New&Clean condition.

Fuel Type Kerosene
System Cogeneration
Power Enhancement at High Ambient Temp. Inlet Air Cooling(Evaporative Type / Chiller Type / Absorbtion Chiller Type)
Model LM2500PJ LM2500RB
Frequency 50Hz 60Hz 50Hz/60Hz
Power Output 20,530kW 21,460kW 31,120kW
Heat Rate 10.59MJ/kWh 10.2MJ/kWh 9.33MJ/kWh
Efficiency at generator terminal 34.0% 35.3% 38.6%
Efficiency for heat recovery 51.9% 51.5% 47.7%
Total thermal efficiency 85.9% 86.8% 86.3%
NOx(O2=16%) 21ppm 21ppm 21ppm

*Condition/Ambient Temp:15℃ Atmospheric Pressure:1013hPa Relative Humidity:60% Steam Pressure:0.8MPaG (Saturated) Feed Water Temp:20℃
*The above performance data is based on the New&Clean condition.

Typical Layout of LM2500 / Cogeneration

No Name
1 Gas Turbine Generator
2 Heat Recovery Steam Generator
3 Fuel Gas Filter Unit
4 Fuel Gas Compressor
5 Chemical Dosing Unit
6 Sampling Unit
7 Boiler Feed Water Pump
8 Cooling Water Pump
9 Cooling Tower
10 Instrument Air Compressor
11 Exhaust Gas Meter
12 Main Transformer
13 Sub Transformer
14 Motor Transformer
15 Switch Gear
16 High Voltage Switch Gear
17 Control Room
TOP
It moves to the head on this page.