IHI Powersystems

start global navi.

グローバルメニューここまでです。

ここから本文です。

MCJ Energy Service Co., Ltd.

mcj

MCJ Energy Service Co., Ltd. implemented the energy system including LM2500PJ Combined Heat and Power (Cogeneration) system located at JSR Yokkaichi Plant in order to cut down on energy costs and to reduce CO2 emissions. This gas turbine power generation system has the capability to produce power output of 21.9 MW and process steam flow of 75 t/h.


LM2500 Combined Heat and Power (Cogeneration) system

コージェネレーションシステム

IHI offered energy system including LM2500 Combined Heat and Power (Cogeneration) system (hereinafter referred to as LM2500CGS system) and steam generator facility to MCJ Energy Service Co., Ltd. for JSR Yokkaichi Plant.
MCJ Energy Service Co., Ltd. applied LM2500CGS system in order to cut down on energy cost and to reduce CO2 emission. Implementation of LM2500CGS system using natural gas enables to reduce the fuel comsuption which existing heavy oil-fired boiler consumes as same amount of steam energy came from LM2500CGS system.
Finally, MCJ Energy Service Co., Ltd. decided to select IHI gas turbine power plant system, because they had evaluated that LM2500CGS was high power output and high efficient, even more, less pollution and low CO2 emission.
LM2500CGS system was constituted of LM2500PJ gas turbine and HRSG(Heat Recovery Steam Generator) with reheating system, which had capability to produce and supply power output of 21.9 MW and process steam flow of 75 t/h.
Supplied electricity is used for power resource supplied to machine and reciprocating compressor, and steam is used for power resouce suppled to equipments on process steam line and existing steam turbines.



Installed gas turbine

導入ガスタービン

LM2500PJ

Specifications
Model LM2500PJ
Power output 20 MW × 1 unit
Fuel Natural gas
Start of operation April 2010

Page Top